ANT8 : 8 Channel Logic Analyzer

ANT8
Larger picture

Note : ANT8 Probe Set Sold Separately

1+   = £125.00 each
5+   = £118.75 each
10+ =
P.O.A.

Extra 10% Discount to bona-fide students
and educational establishments.

 

  • Ultra-portable - fits in a pocket.
  • Powered from USB port - no additional power supply required
  • 8 Channels, 3072 samples deep
  • 500MHz sampling speed
  • Applications run on any recent version of Windows

 

  • Inexpensive
  • Simple or Complex triggering
  • Software upgradeable
  • View captured traces on the display of your PC

 GETTING STARTED GUIDE      SOFTWARE DOWNLOADS 
ANT8 FULL DESCRIPTION ( .chm file )      ANT8 USERS MANUAL    USB INSTRUMENTS WEB

ANT8 Hardware Specification

Acquisition Logic
Sample Rate 500MHz maximum, 100Hz minimum. 5-2.5-1 sequence
Channels 8, numbered 0 to 7
Memory Depth 3072 samples
Threshold 1.4V
Minimum Input 0.2V for Lo, 3.0V for Hi
Input Skew Less than 2ns, channel to channel
Input Impedance 100Kohms in parallel with 10pF
Maximum Input Voltages +40V down to -40V
Triggering
Conditions 0, 1, Rising Edge, Falling Edge, Either Edge, and DON'T CARE for all channels
Pattern Recognisers 2
Edges Trigger on the condition becoming TRUE or on the condition becoming FALSE
Pass Count 0 to 1023
Trigger Logic Multi-state trigger logic with Edge, Pattern, and Complex triggering. Complex triggering includes occurrence counting and minimum and maximum duration measurement
Trigger Position 10% to 90% of buffer, in 10% steps
Environmental
Operating Temperature 5°C to 40°C
Storage Temperature -40°C to 75°C
Size 65 mm x 35mm x 15mm (2.5" x 1.4" x 0.6")
Power Consumption 1.5W maximum
Power Source Via USB cable. No external power supply
Computer Connection USB connection to computer. Includes an attached USB cable
Software Features
Host Computer Logic Analyzer front panel software included for Windows 98/ME/2000/XP
Print Waveforms Yes
Data Output Text File and CSV File
Cursors 1 main cursor plus 1 auxiliary cursor

ANT8 - Probe Clip Set

ANT8Probe
Larger picture

1+   = £12.00 each
5+   = £11.40 each
10+ = P.O.A.

Extra 10% Discount to bona-fide students
and educational establishments.

 

  • 8 channels with red miniature hooked test probes
  • Ground connection with black miniature hooked test probe

 

  • 6 inch (15cm) colour keyed cable
  • Inexpensive

ANT16 : 16 Channel Logic Analyzer

ant16photo
Larger picture

Note : ANT16 Probe Set Sold Separately

1+   = £195.00 each
5+   = £185.25 each
10+ =
P.O.A.

Extra 10% Discount to bona-fide students
and educational establishments.

 

  • Ultra-portable - fits in a pocket.
  • Powered from USB port - no additional power supply required
  • 16 Channels, 2048 samples deep
  • Trigger In and Trigger Out Connections
  • 500MHz asynchronous sampling speed
  • 100MHz synchronous sampling speed

 

  • Applications run on any recent version of Windows
  • Inexpensive
  • Simple or Complex triggering
  • Software upgradeable
  • View captured traces on the display of your PC

 GETTING STARTED GUIDE      SOFTWARE DOWNLOADS 
ANT16 FULL DESCRIPTION ( .chm file )      ANT16 USERS MANUAL    USB INSTRUMENTS WEB

ANT16 Hardware Specification

Acquisition Logic
Asynchronous Sample Rate 500MHz maximum, 100Hz minimum. 5-2.5-1 sequence
Channels 16, numbered 0 to 15
Memory Depth 2048 samples
Threshold 0.8V to 2.5V, in steps of 0.1V
Minimum Input 0.5V below threshold for Lo, 0.5V above threshold for Hi
Trigger Connections Trigger In and Trigger Out. Trigger In is only available in asynchronous clocking mode (using the internal clock). In synchronous clocking mode, this connection becomes Clock In.
Input Skew Less than 2ns, channel to channel
Input Impedance 100Kohms in parallel with 10pF
Maximum Input Voltages +40V down to -40V
Triggering
Conditions 0, 1, Rising Edge, Falling Edge, Either Edge, and DON'T CARE for all channels
Pattern Recognisers 2
Edges Trigger on the condition becoming TRUE or on the condition becoming FALSE
Pass Count 0 to 1023
Trigger Logic Multi-state trigger logic with Edge, Pattern, and Complex triggering. Complex triggering includes occurrence counting and minimum and maximum duration measurement
Trigger Position 10% to 90% of buffer, in 10% steps
Environmental
Operating Temperature 5°C to 40°C
Storage Temperature -40°C to 75°C
Size 65 mm x 35mm x 15mm (2.5" x 1.4" x 0.6")
Power Consumption 2.2W maximum
Power Source Via USB cable. No external power supply
Computer Connection USB connection to computer. Includes an attached USB cable
Software Features
Host Computer Logic Analyzer front panel software included for Windows 98/ME/2000/XP
Print Waveforms Yes
Data Output Text File and CSV File
Cursors 1 main cursor plus 1 auxiliary cursor

ANT16 - Probe Clip Set

ant16probe
Larger picture

1+   = £24.00 each
5+   = £22.80 each
10+ = P.O.A.

Extra 10% Discount to bona-fide students
and educational establishments.

 

  • 16 channels with red miniature hooked test probes
  • 2 ground connections with black miniature hooked test probes
  • Trigger in/clock in connection with yellow miniature hooked test probe

 

  • Trigger out connection with blue miniature hooked test probe
  • 6 inch (15cm) colour keyed cable
  • Inexpensive